Monday, October 27, 2014

BC550 High Temperature ALARM

The circuit is small regulatorof temperature, us warns for the increase of temperature. The control of temperature becomes from the thermistor TH1, that is negative factor. His resistance is altered between in the 10K in temperature 25° C and roughly in the 1K in their 94° C. The trimmer TR1 regulates the precise temperature in which the Q1-2, connected as darlington, conduct, making him relay K1 close also the buzzer BZ, sound. The alarm is activated when the temperature becomes bigger than predetermining. The thermistor it should he is placed far from the remainder circuit, in order that this is not in danger from the temperature.

The supply of circuit becomes from battery 9V, but if he is placed in constant place, then we can him supply with one power supply . In the contacts of relay we can connect what load we want, as a lamb, other circuit k.a. Also can is added a LED, if we want to have also optical clue of excitation. The regulation becomes sinking him thermistor TH1, in water which we know the temperature of (the contacts should are well insulate so that do not have short-circuit) and regulating him trimmer, until excited the circuit. The cable that we connect the circuit with the TH1, should be plate.

Saturday, September 20, 2014

Simple 5 Zone alarm Wiring diagram Schematic

This is a complete alarm system with 5 independent zone ssuitable for a small office or home environment. It uses just 3CM IC`s and features a timed entry / exit zone, 4 immediate zones and a panic button. There are indicators for each zone a“system armed” indicator. The schematic is as follows:

5 Zone alarm Circuit Diagram

5



Circuit Notes:
Each zone uses a normally closed contact. These can be micro switches or standard alarm contacts (usually reed switches).Suitable switches can be bought from alarm shops and concealed indoor frames, or window ledges.Zone 1 is a timed zone which must be used as the entry andexit point of the building. Zones 2 – 5 are immediate zones,which will trigger the alarm with no delay. Some RF immunity isprovided for long wiring runs by the input capacitors, C1-C5. C7and R14 also form a transient suppresser. The key switch acts asthe Set/Unset and Reset switch. For good security thisshould be the metal type with a key.

Operation:
At switch on, C6 will charge via R11, this acts as the exitdelay and is set to around 30 seconds. This can be altered byvarying either C6 or R11. Once the timing period has elapsed,LED6 will light, meaning the system is armed. LED6 may be mountedexternally (at the bell box for example) and providesvisual indication that the system has set. Once set any contactthat opens will trigger the alarm, including Zone 1. To preventtriggering the alarm on entry to the building, the concealedre-entry switch must be operated. This will discharge C6 andstart the entry timer. The re-entry switch could be a concealedreed switch, located anywhere in a door frame, but invisibleto the eye. The panic switch, when pressed, will trigger thealarm when set. Relay contacts RLA1 provide the latch, RLA2operate the siren or buzzer.

Wednesday, September 17, 2014

M 3482 Alarm Water Sensor Circuit

This is an easy musical alarm circuit that produces a musical tone when water or some conducting liquid comes in contact with the two sensor wires provided. The circuit is based on four transistors and one melody generator IC (M 3482).

When water comes in contact with the sensors wires A & B, the base of Q1 gets connected with the negative and it conducts. This makes Q2 and Q3 ON. When Q3 is ON the power is available for the music generator circuit and it starts producing 12 totally different melodies one after another. The music continues as long as theres water between the sensor wires. The POT R12 can be used as a volume controller.

Monday, September 15, 2014

Simple Fire Alarm

Here is a simple schema which can be used as a Fire Alarm. 3 Volt is enough to operate. There is not much to the schema. The IC UM66 is connected to its supply and its output fed to a transistor for amplification.

Circuit diagram :

Simple

Simple Fire Alarm Circuit Diagram

UM66 is a complete miniature tone generator with a ROM of 64 notes, oscillator and a preamplifier. For amplification we have used a NPN transistor which is BC548. Here BC548 makes a common emitter schema. For limiting the base current we have used a resistance of 220 Ohms so that transistor will not get damaged even if IC is wrong connected.

For heat sensor we have used tube light starter in place of manual switch. In a starter there is a metal plate and a pin with small gap. When starter gets heated then metal plate of starter expands and get in contact with the pin and schema is completed and we get audio from speaker. For fast sensing we can use starter without its glass body by carefully breaking glass cover.

Friday, September 12, 2014

Zero degree Celsius alarm




This is a schema of Zero degree Celsius alarm . this is very useful schema for all.Because we all can get different uses from this schema.When you fix this schema You have to face to a problem it is none but the power supply.Here I have given a power supply so you can avoid that problem.






Power supply



Tuesday, September 9, 2014

How to build An Expandable Multi Zone Modular Burglar Alarm

Description

The Basic Alarm Circuit has an automatic Exit/Entry Zone - an Instant Alarm Zone that will accept both normally-closed and normally-open triggering devices - and an "Always On" 24-hour Personal Attack/Tamper Zone. By using the Expansion Modules - you can add as many extra alarm zones as you require.

Schematic Diagram

Expandable

The Alarm is armed and disarmed by SW1. Before you move the switch to the "set" position - all the green LEDs should be lighting. You then have up to about a minute to leave the building. As you do so - the Buzzer will sound. It should stop sounding when you close the door behind you. This indicates that the Exit/Entry loop has been successfully restored within the time allowed. 


When you re-enter the building - you have up to about a minute to move SW1 to the "off" position. If SW1 is not switched off in time - the relay will energize - and the main bell will ring. It will continue ringing for up to about 40 minutes. But it can be turned off at any time by SW1. 

The "Instant" zone has no Entry Delay. The moment one of its normally-open switches is closed - the main bell will ring. Similarly - the moment one of its normally-closed switches is opened - the main bell will ring. If you dont want to use normally-open switches - leave out R8, C8 and Q2 - and fit a link between Led 3 and C7.
The 24 Hour Personal Attack and Tamper protection is provided by the SCR/Thyristor. If one of the switches in the normally-closed loop is opened - current through R11 will trigger the SCR - and the main bell will ring. In this case the bell has no time limit. To reset the PA/Tamper zone - first restore the normally-closed loop - then press SW2 momentarily. This will interrupt the current and reset the SCR.

Two-Zone Expansion Module


Expandable

The basic schema will be satisfactory in many situations. However, if you have a large building to protect - its much easier to find a fault - when the system is divided into zones - and the control panel can "remember" which zone has caused the activation. 

The expansion modules are designed to do this. Although they will work with the existing instant zone - they are intended to replace it. When a zone is triggered - its red LED will light and remain lit - to indicate that the zone has been activated. 

The idea is that - once youve noted the zone in question - you then press the reset button and turn off the LED. The reset button simply turns off the LED. It doesnt reset the zone. The zone resets automatically when the trigger schema is restored. If youre using more than one expansion module - they can all share a single reset button.
Expandable

Inertia-Sensor Module

Tuesday, September 2, 2014

Low cost fire alarm circuit




When there is a fire breakout in the room the temperature increases.This ultra compact and low cost fire alarm senses fire breakout based on this fact.







Transistor BC177 (Q1) is used as the fire sensor here.When the temperature increases the leakage current of this transistor also increases.The schema is designed so that when there is an increase in the leakage current of Q1 ,transistor Q2 will get biased.As a result when there is a fire breakout the transistor Q2 will be on.The emitter of Q2 (BC 108)is connected to the base of Q3(AC 128).So when Q2 is ON Q3 will be also ON.The transistor Q3 drives the relay which is used to drive the load ie,light,bell,horn etc as an indication of the fire.The diode D1 is used as a free wheeling diode to protect it from back EMF generated when relay is switche



Notes.

* The Preset R1 can be used to desired temperature level for setting the alarm ON.
* This is not a latching alarm,ie;when the temperature in the vicinity of the sensor decreases below the set point the alarm stops.
* The schema can be powered using a 9V battery or a 9V battery eliminator.
* All capacitors are electrolytic and must be rated at least 10V.
* The load can be connected through the C,NC,NO points of the relay according to your need.
* The calibration can be done using a soldering iron,and a thermo meter.Switch ON the power supply.Keep the tip of soldering iron near to the Q1.Same time also keep the thermometer close to it.When the temperature reaches your desired value adjust R1 so that relay gets ON.Done!

Thursday, August 28, 2014

Long range Burglar Alarm Using Laser Torch

Laser torch-based burglar alarms normally work in darkness only. But this long-range photoelectric alarm can work reliably in daytime also to warn you against intruders in your big compounds, etc. The alarm comprises laser transmitter and receiver units, which are to be mounted on the opposite pillars of the entry gate. Whenever anyone enters to interrupt the transmitted laser beam falling on the receiver, the buzzer in the receiver schema sounds an alarm.

The range of this burglar alarm is around 30 metres, which means you can place the transmitter and the receiver up to 30 metres apart. Since the laser torch can transmit light up to a distance of 500 metres, this range can be increased by orienting the phototransistor sensor properly. To avoid false triggering by sunlight, mount the phototransistor sensor such that it doesn’t directly face sunlight.

Circuit
Fig. 1: Circuit of laser torch based transmitter

The transmitter schema is powered by 3V DC. The astable multivibrator built around timer 7555 (IC1) produces 5.25kHz frequency. CMOS version of timer 7555 is used for low-voltage operation. The body of the laser torch is connected to the emitter of npn transistor T1 and the spring-loaded lead protruding from inside the torch is connected to the ground.

The receiver schema is powered by 12V DC. It uses photoDarlington 2N5777 (T2) to sense the laser beam transmitted from the laser torch. The output beam signals from photoDarlington are given to the two-stage amplifier followed by switching schema, etc. As long as the laser beam falls on photoDarlington T2, relay RL1 remains un-energised and the buzzer does not sound. Also, LED1 doesn’t glow.

Receiver
Fig. 2: Receiver schema

When anyone interrupts the laser beam falling on photoDarlington T2, npn transistor T6 stops conducting and npn transistor T7 is driven into conduction. As a result, LED1 glows and relay RL1 energises to sound the buzzer for a few seconds (determined by the values of resistor R15 and capacitor C10). At the same time, the large indication load (230V AC alarm for louder sounds or any other device for momentary indication) also gets activated as it is connected to 230V AC mains via normally opened (N/O) contact of relay RL1.


Sourced By: EFY Author: Pradeep G.

Tuesday, August 26, 2014

Anti Theft Alarm for Vehicles Wiring diagram Schematic

This simple and inexpensive anti-theft schema for vehicles sounds an alarm simulating a police siren whenever someone attempts theft of your vehicle. The alarm sounds continuously for a few seconds even when the intruder switches off the ignition key. The schema uses only a few components and can be easily assembled and installed on a car with negative grounding.

Anti-Theft Alarm for Vehicles Circuit Diagram


Anti-Theft


The schema consists of an SCR-based trigger schema and audio alarm schema. When the ignition key of the vehicle is switched off, base voltage of transistor T1 is low and it remains turned off. When the ignition key is switched on for starting the vehicle, a positive voltage is applied to the base of transistor T1 through diode D1, switch S2, and resistor R1, which slowly charges capacitor C1. As a result, the base voltage of T1 rises. As soon as the biasing voltage crosses cut-in voltage, T1 turns on and SCR fires, giving 12V DC to the alarm schema.

The alarm schema is built around the siren-sound generator ROM UM3561 (IC1). It has a built-in oscillator, whose oscillation depends on resistor R5. Resistor R6 and zener diode ZD1 limit the voltage to IC1 to a safer level of 3.3V. The output from IC1 is fed to a transistor amplifier built around transistors T2 and T3.

The schema gives sufficient time delay to switch on the alarm and to leave the vehicle. The alarm, once triggered, will sound until switch S1 is pressed to switch off the power supply.

Capacitor C2 is provided to sound the alarm even when the intruder switches off the ignition key. When the ignition key is switched off immediately, C2 discharges through R4 and keeps the alarm activated for half a minute. Reset switch S3 can be used to reset the alarm if needed.

The schema can be assembled on a vero board. Use a small heat-sink for transistor T1. Connect point A to the ignition switch terminal that goes to the ignition coil. The hidden switch S1 is used for power on/off and switch S2 enables the schema.

Note. Keep switches S1 and S2 on before leaving the vehicle. And don’t forget to switch off S1 and S2 before starting the vehicle.

The schema costs around Rs 50.



Sourced BY: EFY: Author:  D. Mohan Kumar

Friday, August 22, 2014

5 Zone Alarm System

This is a complete alarm system with 5 independent zones suitable for a small office or home environment. It uses just 3 CMOS ICs and features a timed entry / exit zone, 4 immediate zones and a panic button. There are indicators for each zone a "system armed" indicator. The schematic is as follows:

5 Zone Alarm System Circuit Diagram


5


Circuit Notes
Each zone uses a normally closed contact. These can be micro switches or standard alarm contacts (usually reed switches). Suitable switches can be bought from alarm shops and concealed in door frames, or window ledges.

Zone 1 is a timed zone which must be used as the entry and exit point of the building. Zones 2 - 5 are immediate zones, which will trigger the alarm with no delay. Some RF immunity is provided for long wiring runs by the input capacitors, C1-C5. C7 and R14 also form a transient suppressor. The key switch acts as the Set/Unset and Reset switch. For good security this should be the metal type with a key.

Operation
At switch on, C6 will charge via R11, this acts as the exit delay and is set to around 30 seconds. This can be altered by varying either C6 or R11. Once the timing period has elapsed, LED6 will light, meaning the system is armed. LED6 may be mounted externally (at the bell box for example) and provides visual indication that the system has set. Once set any contact that opens will trigger the alarm, including Zone 1. To prevent triggering the alarm on entry to the building, the concealed re-entry switch must be operated. This will discharge C6 and start the entry timer. The re-entry switch could be a concealed reed switch, located anywhere in a door frame, but invisible to the eye. The panic switch, when pressed, will trigger the alarm when set. Relay contacts RLA1 provide the latch, RLA2 operate the siren or buzzer.


Author : Andy Collinson