The supply of circuit becomes from battery 9V, but if he is placed in constant place, then we can him supply with one power supply . In the contacts of relay we can connect what load we want, as a lamb, other circuit k.a. Also can is added a LED, if we want to have also optical clue of excitation. The regulation becomes sinking him thermistor TH1, in water which we know the temperature of (the contacts should are well insulate so that do not have short-circuit) and regulating him trimmer, until excited the circuit. The cable that we connect the circuit with the TH1, should be plate.
Monday, October 27, 2014
BC550 High Temperature ALARM
The supply of circuit becomes from battery 9V, but if he is placed in constant place, then we can him supply with one power supply . In the contacts of relay we can connect what load we want, as a lamb, other circuit k.a. Also can is added a LED, if we want to have also optical clue of excitation. The regulation becomes sinking him thermistor TH1, in water which we know the temperature of (the contacts should are well insulate so that do not have short-circuit) and regulating him trimmer, until excited the circuit. The cable that we connect the circuit with the TH1, should be plate.
Saturday, September 20, 2014
Simple 5 Zone alarm Wiring diagram Schematic
Wednesday, September 17, 2014
M 3482 Alarm Water Sensor Circuit
When water comes in contact with the sensors wires A & B, the base of Q1 gets connected with the negative and it conducts. This makes Q2 and Q3 ON. When Q3 is ON the power is available for the music generator circuit and it starts producing 12 totally different melodies one after another. The music continues as long as theres water between the sensor wires. The POT R12 can be used as a volume controller.
Monday, September 15, 2014
Simple Fire Alarm
Here is a simple schema which can be used as a Fire Alarm. 3 Volt is enough to operate. There is not much to the schema. The IC UM66 is connected to its supply and its output fed to a transistor for amplification.
Circuit diagram :
Simple Fire Alarm Circuit Diagram
UM66 is a complete miniature tone generator with a ROM of 64 notes, oscillator and a preamplifier. For amplification we have used a NPN transistor which is BC548. Here BC548 makes a common emitter schema. For limiting the base current we have used a resistance of 220 Ohms so that transistor will not get damaged even if IC is wrong connected.
For heat sensor we have used tube light starter in place of manual switch. In a starter there is a metal plate and a pin with small gap. When starter gets heated then metal plate of starter expands and get in contact with the pin and schema is completed and we get audio from speaker. For fast sensing we can use starter without its glass body by carefully breaking glass cover.
Friday, September 12, 2014
Zero degree Celsius alarm
This is a schema of Zero degree Celsius alarm . this is very useful schema for all.Because we all can get different uses from this schema.When you fix this schema You have to face to a problem it is none but the power supply.Here I have given a power supply so you can avoid that problem.
Power supply
Tuesday, September 9, 2014
How to build An Expandable Multi Zone Modular Burglar Alarm
Description
Schematic Diagram
The Alarm is armed and disarmed by SW1. Before you move the switch to the "set" position - all the green LEDs should be lighting. You then have up to about a minute to leave the building. As you do so - the Buzzer will sound. It should stop sounding when you close the door behind you. This indicates that the Exit/Entry loop has been successfully restored within the time allowed.
Two-Zone Expansion Module
The basic schema will be satisfactory in many situations. However, if you have a large building to protect - its much easier to find a fault - when the system is divided into zones - and the control panel can "remember" which zone has caused the activation.
Inertia-Sensor Module
Tuesday, September 2, 2014
Low cost fire alarm circuit
When there is a fire breakout in the room the temperature increases.This ultra compact and low cost fire alarm senses fire breakout based on this fact.
Transistor BC177 (Q1) is used as the fire sensor here.When the temperature increases the leakage current of this transistor also increases.The schema is designed so that when there is an increase in the leakage current of Q1 ,transistor Q2 will get biased.As a result when there is a fire breakout the transistor Q2 will be on.The emitter of Q2 (BC 108)is connected to the base of Q3(AC 128).So when Q2 is ON Q3 will be also ON.The transistor Q3 drives the relay which is used to drive the load ie,light,bell,horn etc as an indication of the fire.The diode D1 is used as a free wheeling diode to protect it from back EMF generated when relay is switche
Notes.
* The Preset R1 can be used to desired temperature level for setting the alarm ON.
* This is not a latching alarm,ie;when the temperature in the vicinity of the sensor decreases below the set point the alarm stops.
* The schema can be powered using a 9V battery or a 9V battery eliminator.
* All capacitors are electrolytic and must be rated at least 10V.
* The load can be connected through the C,NC,NO points of the relay according to your need.
* The calibration can be done using a soldering iron,and a thermo meter.Switch ON the power supply.Keep the tip of soldering iron near to the Q1.Same time also keep the thermometer close to it.When the temperature reaches your desired value adjust R1 so that relay gets ON.Done!
Thursday, August 28, 2014
Long range Burglar Alarm Using Laser Torch
Tuesday, August 26, 2014
Anti Theft Alarm for Vehicles Wiring diagram Schematic
Anti-Theft Alarm for Vehicles Circuit Diagram
The schema consists of an SCR-based trigger schema and audio alarm schema. When the ignition key of the vehicle is switched off, base voltage of transistor T1 is low and it remains turned off. When the ignition key is switched on for starting the vehicle, a positive voltage is applied to the base of transistor T1 through diode D1, switch S2, and resistor R1, which slowly charges capacitor C1. As a result, the base voltage of T1 rises. As soon as the biasing voltage crosses cut-in voltage, T1 turns on and SCR fires, giving 12V DC to the alarm schema.
The alarm schema is built around the siren-sound generator ROM UM3561 (IC1). It has a built-in oscillator, whose oscillation depends on resistor R5. Resistor R6 and zener diode ZD1 limit the voltage to IC1 to a safer level of 3.3V. The output from IC1 is fed to a transistor amplifier built around transistors T2 and T3.
The schema gives sufficient time delay to switch on the alarm and to leave the vehicle. The alarm, once triggered, will sound until switch S1 is pressed to switch off the power supply.
Capacitor C2 is provided to sound the alarm even when the intruder switches off the ignition key. When the ignition key is switched off immediately, C2 discharges through R4 and keeps the alarm activated for half a minute. Reset switch S3 can be used to reset the alarm if needed.
The schema can be assembled on a vero board. Use a small heat-sink for transistor T1. Connect point A to the ignition switch terminal that goes to the ignition coil. The hidden switch S1 is used for power on/off and switch S2 enables the schema.
Note. Keep switches S1 and S2 on before leaving the vehicle. And don’t forget to switch off S1 and S2 before starting the vehicle.
The schema costs around Rs 50.
Friday, August 22, 2014
5 Zone Alarm System
5 Zone Alarm System Circuit Diagram
Circuit Notes
Zone 1 is a timed zone which must be used as the entry and exit point of the building. Zones 2 - 5 are immediate zones, which will trigger the alarm with no delay. Some RF immunity is provided for long wiring runs by the input capacitors, C1-C5. C7 and R14 also form a transient suppressor. The key switch acts as the Set/Unset and Reset switch. For good security this should be the metal type with a key.
Operation
At switch on, C6 will charge via R11, this acts as the exit delay and is set to around 30 seconds. This can be altered by varying either C6 or R11. Once the timing period has elapsed, LED6 will light, meaning the system is armed. LED6 may be mounted externally (at the bell box for example) and provides visual indication that the system has set. Once set any contact that opens will trigger the alarm, including Zone 1. To prevent triggering the alarm on entry to the building, the concealed re-entry switch must be operated. This will discharge C6 and start the entry timer. The re-entry switch could be a concealed reed switch, located anywhere in a door frame, but invisible to the eye. The panic switch, when pressed, will trigger the alarm when set. Relay contacts RLA1 provide the latch, RLA2 operate the siren or buzzer.