Saturday, September 20, 2014

Simple 5 Zone alarm Wiring diagram Schematic

This is a complete alarm system with 5 independent zone ssuitable for a small office or home environment. It uses just 3CM IC`s and features a timed entry / exit zone, 4 immediate zones and a panic button. There are indicators for each zone a“system armed” indicator. The schematic is as follows:

5 Zone alarm Circuit Diagram

5



Circuit Notes:
Each zone uses a normally closed contact. These can be micro switches or standard alarm contacts (usually reed switches).Suitable switches can be bought from alarm shops and concealed indoor frames, or window ledges.Zone 1 is a timed zone which must be used as the entry andexit point of the building. Zones 2 – 5 are immediate zones,which will trigger the alarm with no delay. Some RF immunity isprovided for long wiring runs by the input capacitors, C1-C5. C7and R14 also form a transient suppresser. The key switch acts asthe Set/Unset and Reset switch. For good security thisshould be the metal type with a key.

Operation:
At switch on, C6 will charge via R11, this acts as the exitdelay and is set to around 30 seconds. This can be altered byvarying either C6 or R11. Once the timing period has elapsed,LED6 will light, meaning the system is armed. LED6 may be mountedexternally (at the bell box for example) and providesvisual indication that the system has set. Once set any contactthat opens will trigger the alarm, including Zone 1. To preventtriggering the alarm on entry to the building, the concealedre-entry switch must be operated. This will discharge C6 andstart the entry timer. The re-entry switch could be a concealedreed switch, located anywhere in a door frame, but invisibleto the eye. The panic switch, when pressed, will trigger thealarm when set. Relay contacts RLA1 provide the latch, RLA2operate the siren or buzzer.

Tuesday, September 9, 2014

How to build An Expandable Multi Zone Modular Burglar Alarm

Description

The Basic Alarm Circuit has an automatic Exit/Entry Zone - an Instant Alarm Zone that will accept both normally-closed and normally-open triggering devices - and an "Always On" 24-hour Personal Attack/Tamper Zone. By using the Expansion Modules - you can add as many extra alarm zones as you require.

Schematic Diagram

Expandable

The Alarm is armed and disarmed by SW1. Before you move the switch to the "set" position - all the green LEDs should be lighting. You then have up to about a minute to leave the building. As you do so - the Buzzer will sound. It should stop sounding when you close the door behind you. This indicates that the Exit/Entry loop has been successfully restored within the time allowed. 


When you re-enter the building - you have up to about a minute to move SW1 to the "off" position. If SW1 is not switched off in time - the relay will energize - and the main bell will ring. It will continue ringing for up to about 40 minutes. But it can be turned off at any time by SW1. 

The "Instant" zone has no Entry Delay. The moment one of its normally-open switches is closed - the main bell will ring. Similarly - the moment one of its normally-closed switches is opened - the main bell will ring. If you dont want to use normally-open switches - leave out R8, C8 and Q2 - and fit a link between Led 3 and C7.
The 24 Hour Personal Attack and Tamper protection is provided by the SCR/Thyristor. If one of the switches in the normally-closed loop is opened - current through R11 will trigger the SCR - and the main bell will ring. In this case the bell has no time limit. To reset the PA/Tamper zone - first restore the normally-closed loop - then press SW2 momentarily. This will interrupt the current and reset the SCR.

Two-Zone Expansion Module


Expandable

The basic schema will be satisfactory in many situations. However, if you have a large building to protect - its much easier to find a fault - when the system is divided into zones - and the control panel can "remember" which zone has caused the activation. 

The expansion modules are designed to do this. Although they will work with the existing instant zone - they are intended to replace it. When a zone is triggered - its red LED will light and remain lit - to indicate that the zone has been activated. 

The idea is that - once youve noted the zone in question - you then press the reset button and turn off the LED. The reset button simply turns off the LED. It doesnt reset the zone. The zone resets automatically when the trigger schema is restored. If youre using more than one expansion module - they can all share a single reset button.
Expandable

Inertia-Sensor Module

Friday, August 22, 2014

5 Zone Alarm System

This is a complete alarm system with 5 independent zones suitable for a small office or home environment. It uses just 3 CMOS ICs and features a timed entry / exit zone, 4 immediate zones and a panic button. There are indicators for each zone a "system armed" indicator. The schematic is as follows:

5 Zone Alarm System Circuit Diagram


5


Circuit Notes
Each zone uses a normally closed contact. These can be micro switches or standard alarm contacts (usually reed switches). Suitable switches can be bought from alarm shops and concealed in door frames, or window ledges.

Zone 1 is a timed zone which must be used as the entry and exit point of the building. Zones 2 - 5 are immediate zones, which will trigger the alarm with no delay. Some RF immunity is provided for long wiring runs by the input capacitors, C1-C5. C7 and R14 also form a transient suppressor. The key switch acts as the Set/Unset and Reset switch. For good security this should be the metal type with a key.

Operation
At switch on, C6 will charge via R11, this acts as the exit delay and is set to around 30 seconds. This can be altered by varying either C6 or R11. Once the timing period has elapsed, LED6 will light, meaning the system is armed. LED6 may be mounted externally (at the bell box for example) and provides visual indication that the system has set. Once set any contact that opens will trigger the alarm, including Zone 1. To prevent triggering the alarm on entry to the building, the concealed re-entry switch must be operated. This will discharge C6 and start the entry timer. The re-entry switch could be a concealed reed switch, located anywhere in a door frame, but invisible to the eye. The panic switch, when pressed, will trigger the alarm when set. Relay contacts RLA1 provide the latch, RLA2 operate the siren or buzzer.


Author : Andy Collinson